Determination of total rare earth oxides in organic solution was achieved by the oxalate gravimetric method.Firstly the sample was dried in the electric furnace and then burn at a high temperature in order to destroy organic matter.Secondly, it was melt by the alkali and precipitated by the hydrofluoric acid,ammonia and oxalic acid in order to separate from the interference elements.Lastly, the sediments were burn to a constant weight,producing of total rare earth oxides.The results show that this proposed method can be used to determine of less than 1, of the total rare earth oxides in organic solution,with RSD of 0.96,-2.45, and 95.00,-98.24, recovery.The accuracy and precision of the method are able to satisfy with the detection requirements.